Криоконсервирование кордовой крови с использованием ПЭО-1500

The method without washing-out for the whole cord blood cryopreservation with PEO-1500, enabling to preserve up to 99 and 93% erythrocytes after freeze-thawing and by the transfusion test data, correspondingly, has been designed. The integrity of biologically active substances in plasm at the contro...

Full description

Saved in:
Bibliographic Details
Date:2007
Main Authors: Ryazantsev, V. V., Babijchuk, L. A., Zubova, O. L., Gurina, T. M.
Format: Article
Language:English
Published: Publishing House ‘Akademperiodyka’ of the National Academy of Sciences of Ukraine; Institute for Problems of Cryobiology and Cryomedicine 2007
Subjects:
Online Access:https://cryo.org.ua/journal/index.php/probl-cryobiol-cryomed/article/view/497
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Problems of Cryobiology and Cryomedicine

Institution

Problems of Cryobiology and Cryomedicine
Description
Summary:The method without washing-out for the whole cord blood cryopreservation with PEO-1500, enabling to preserve up to 99 and 93% erythrocytes after freeze-thawing and by the transfusion test data, correspondingly, has been designed. The integrity of biologically active substances in plasm at the control level has been established. After cryopreservation with the mentioned above method the immunofluorescent test has demonstrated the integrity of up to 70% blood lymphocytes, including cord blood stem cells (CD34+).