ДЖЕРЕЛО ЖИВЛЕННЯ ДЛЯ ІМПУЛЬСНИХ ЕЛЕКТРОРОЗРЯДНИХ ТЕХНОЛОГІЙ ОБРОБКИ ВОДИ

Short pulse high-voltage generator with a secondary inductive energy storage, which is commuting with SOS-diode, was modeled. It was researched an influence of R,L,C-parameters of generator and an resistance of load on the characteristics of the output pulse voltage (amplitude, lengths of the front...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2014
Hauptverfasser: Божко , І.В., Кобильчак , В.В.
Format: Artikel
Sprache:Ukrainian
Veröffentlicht: Інститут електродинаміки НАН України, Київ 2014
Schlagworte:
Online Zugang:https://techned.org.ua/index.php/techned/article/view/1025
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Technical Electrodynamics

Institution

Technical Electrodynamics
Beschreibung
Zusammenfassung:Short pulse high-voltage generator with a secondary inductive energy storage, which is commuting with SOS-diode, was modeled. It was researched an influence of R,L,C-parameters of generator and an resistance of load on the characteristics of the output pulse voltage (amplitude, lengths of the front and of the pulse) and the ratio of energy transfer from the primary energy storage (capacitor) to the load. It was defined the optimal value of elements of circuit in which the characteristics of generator are acceptable (steepness of the front pulse about 2·1011 V/s the pulse length near 100 ns) for use in water treatment technologies by pulse electric discharge. It is shown that the coefficient of energy transmission in a pulse generator may exceed 80%. The calculation results are confirmed by experimental studies. References 10, figures 6.