МАГНИТОСТАТИЧЕСКОЕ ЭКРАНИРОВАНИЕ ЗОНЫ СВАРКИ ВБЛИЗИ ШИНОПРОВОДА

Unlocked magnetostatic shields meant for protection of technological welding process of external busbars of aluminum electrolysis from detrimental effect of their magnetic field have been examined both analytically and experimentally. Engineering methodology of such shields' calculation confirm...

Full description

Saved in:
Bibliographic Details
Date:2011
Main Authors: Волохов, С.А., Деркач, В.В., Добродеев, П.Н.
Format: Article
Language:Ukrainian
Published: Інститут електродинаміки НАН України, Київ 2011
Subjects:
Online Access:https://techned.org.ua/index.php/techned/article/view/1431
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Technical Electrodynamics

Institution

Technical Electrodynamics