Adduced description and results of experimental research of high-voltage transducer. It is shown that the formation process of charge of the first capacitor storage energy with using IGBT devices leads to reduction of energy losses and increases the efficiency of the high-voltage converter. Done the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2015
Hauptverfasser: Переверзєв, А.В., Литвиненко, Т.М.
Format: Artikel
Sprache:Ukrainian
Veröffentlicht: Інститут електродинаміки НАН України, Київ 2015
Schlagworte:
Online Zugang:https://techned.org.ua/index.php/techned/article/view/975
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Technical Electrodynamics

Institution

Technical Electrodynamics
Beschreibung
Zusammenfassung:Adduced description and results of experimental research of high-voltage transducer. It is shown that the formation process of charge of the first capacitor storage energy with using IGBT devices leads to reduction of energy losses and increases the efficiency of the high-voltage converter. Done the comparison of experimental data with simulation results. Testing the experimental sample showed a significant efficiency of the developed high-voltage converter for neutralization of sulfur dioxide. The degree of neutralization reaches 96 %. References 12, figures 5.