Сравнительные исследования двухканального щелевого теплообменника и существующего на рынке аналога
The thermal characteristics of a newly developed two‑channel slot water‑cooled aluminum heat exchanger for a high‑power electronic component and a commercially available copper water‑cooled heat exchanger (Titan) have been experimentally investigated in both closed and open water‑cooling systems. Gr...
Saved in:
| Date: | 2008 |
|---|---|
| Main Authors: | , , , , |
| Format: | Article |
| Language: | Ukrainian |
| Published: |
PE "Politekhperiodika", Book and Journal Publishers
2008
|
| Subjects: | |
| Online Access: | https://www.tkea.com.ua/index.php/journal/article/view/TKEA2008.3.50 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Technology and design in electronic equipment |
Institution
Technology and design in electronic equipment| Summary: | The thermal characteristics of a newly developed two‑channel slot water‑cooled aluminum heat exchanger for a high‑power electronic component and a commercially available copper water‑cooled heat exchanger (Titan) have been experimentally investigated in both closed and open water‑cooling systems. Graphical dependencies of the dissipated power on the average temperature of the heat‑flow simulator are presented. It is shown that the slot heat exchanger provides higher values of dissipated power at the same simulator temperature. At a simulator temperature of +60 °C for the heat‑generating component, the dissipated power in the closed cooling system increased from 112 to 172 W, and in the open system from 234 to 307.4 W. |
|---|