УМЕНЬШЕНИЕ СИСТЕМАТИЧЕСКОЙ ПОГРЕШНОСТИ ЕМКОСТНОГО ДАТЧИКА БИЕНИЙ ВАЛА ЗА СЧЕТ ИЗМЕНЕНИЯ ФОРМЫ АКТИВНОГО ЭЛЕКТРОДА
Capacitive sensor of radical shaft beats of huge electric machines which has an active scalene rectangle electrode has been suggested. While measuring a shorter side of rectangle arranges perpendicular to longitudinal axis of shaft. The calculation of sensor transfer function has been carried out. A...
Gespeichert in:
| Datum: | 2010 |
|---|---|
| Автори та афіліації: |
|
| Ключові слова: | keywords |
| Hauptverfasser: | , |
| Format: | Artikel |
| Sprache: | Ukrainisch |
| Veröffentlicht: |
Інститут електродинаміки НАН України, Київ
2010
|
| Schlagworte: | |
| Online Zugang: | https://techned.org.ua/index.php/techned/article/view/1416 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Technical Electrodynamics |
| Завантажити файл: |
|
Institution
Technical Electrodynamics| _version_ | 1870204924573253632 |
|---|---|
| author | Левицкий, А.С. Новик, А.И. |
| author_facet | Левицкий, А.С. Новик, А.И. |
| author_institution_txt_mv | [
{
"author": "А.С. Левицкий",
"institution": "Інститут електродинаміки НАН України, пр. Перемоги, 56, Київ, 03057, Україна"
},
{
"author": "А.И. Новик",
"institution": "Інститут електродинаміки НАН України, пр. Перемоги, 56, Київ, 03057, Україна"
}
] |
| author_sort | Левицкий, А.С. |
| baseUrl_str | https://techned.org.ua/index.php/techned/oai |
| collection | OJS |
| datestamp_date | 2023-01-28T16:55:22Z |
| description | Capacitive sensor of radical shaft beats of huge electric machines which has an active scalene rectangle electrode has been suggested. While measuring a shorter side of rectangle arranges perpendicular to longitudinal axis of shaft. The calculation of sensor transfer function has been carried out. Analysis of the error caused by curvature of target cylindrical surface has been performed. Also, it has been shown that the error depends only on the side dimension of active electrode which is perpendicular to longitudinal axis of shaft. Comparison of the error with the capacitive sensor error of shaft beats with an active rounded electrode having the same area has been made. Also, it has been shown that the error of sensor with rectangular electrode is several times smaller. References 6, figures 4. |
| first_indexed | 2026-06-16T01:26:29Z |
| format | Article |
| fulltext |
ISSN 1607-7970. . . 2011. 1 83
681.586.772
1, , 2,
1, 2 ,
. , 56, -57, 03680,
,
. -
.
. , -
. , , -
.
. ,
. . 6, . 4.
: , , , , .
-
,
.
, -
, . -
[1,2]
50–60% .
-
[3,4,6]. -
-
– « » -
. , ,
( ), -
. -
, -
. 1XC d -
1 ( )XC f d ,
. -
.
, . -
( ) , r.
, ( ) -
, . ,
-
( , ). [4]
, , . -
. , -
, R r -
( R ).
R , -
r .
, , -
, , -
© ., ., 2011
84 ISSN 1607-7970. . . 2011. 1
, . -
,
. [5].
, -
. -
( , ). -
, , -
, . , -
( , -
), -
.
-
-
, .
. 1. 1
2
a b , R
d 1
2 ( . 1).
XYZ O ,
. -
1 3 -
x y .
, -
iC
x y 2 , -
iz
1
0i iC x yz , (1)
: 0 =8,8542 –
; – -
( , ).
-
OAB RBAO , ,
2 2
i iz d R R x . (2)
0 2 2i
i
x yC
d R R x
. (3)
-
,
1 2,
,
1 1 2 20; 0; / 2; / 2x y x a y b . -
, -
b / 2 a / 2
1X 0 2 2
0 0
dxdyC 4
d+ R- R - x
=
/ 2
0 2 2
0
2
a dxb
d R R x
. 1
ISSN 1607-7970. . . 2011. 1 85
= 20
2 2 2 2
2 2
2 2 2 4
b a ad R Arctg d dR Arctg
d dR d dR R a
(4)
2 2 22 4
a d R
d R Arctg
d dR R a
.
. 2
-
1XC d -
R =0,35 -
3 34 10 19,6 10 ( 1)
3 36,4 10 31,4 10 ( 2).
, -
-
, -
-
, -
11 XC . -
,
,
, -
-
.
10 0 /C ab d . (5)
1 d (4) (5)
/ 2
2 2
0
1 / 2
2 2
0
2
100%
2
a
a
dxa d
d R R x
dxd
d R R x
.
(6)
-
MAX MINd d d ,
MAX , MINd d . -
31 10MINd ,
( )f a ( . 3)
R .
,
a b , -
-
,
r , 2a b r . / 2B a r ,
a
. 2a rB , / 2b r B .
(6)
. 2
. 3
86 ISSN 1607-7970. . . 2011. 1
1
1 2 2 2 2
0 0
100%
Br Brdx dxBr d d
d R R x d R R x
. (7)
2 -
r [4]:
1
2 20 2 2 100%X XC C C
1
2 2 2 2
2
2 2 2 2
0 0
4 4 100%
r rr x r xr d dx d dx
d R R x d R R x
. (8)
(7) (8), -
2
1 . 2 1/ ( , )f B r
31 10MINd . 4,
,
2 1/ -
B r . -
B 0,2 0,6 2 1/ -
18 2.
, -
,
, ,
,
-
,
. -
-
B 0,3–0,5.
1. . ( ) . — .: -
, 2001. 152 .
Alekseev B.A. Definition of condition (diagnostics) of power hydrogenerators. – Moskva: Nauchno-uchebnyj
tsentr ENAS, 2001. – 152 p. (Rus.)
2. ., . /
. – : , 2008. 3(53). C. 79–84.
Beloglazov A.V., Glazyrin G.V. Creation of apparatus for monitoring of run-out shaft in hydroaggregate /
Sbornik nauchnykh trudov Novosibirskogo Gosudarstvennogo Tekhnicheskogo Universiteta. – 2008. – 3(53). – P.
79–84. (Rus.)
3. . -
// . – 2009. – 1. – . 14–20
Levytskyi A.S. Apparatus and methods for control of radial run-out of cylindrical surface shafts of power
hydrogenerators // Hidroenergetica Ukrainy. – 2009. – 1. – P. 14–20. (Ukr.)
4. , .
// . . – 2010. – 4. – . 66–70.
Levitskii A.S., Novik A.I. Estimation of error measurement by capacitive sensors of run-out shafts of electrical
machines // Tekhnichna elektrodynamika. – 2010. – 4. – P. 66–70. (Rus.)
5. ., ., . -
// . – 2009. – 3. – . 58 60.
Novik A.I., Levytskyi A.S, Voshchynskyi K.V. Sources of errors of capacitive measuring instrument of gap in
hydrogenerators // Hidroenergetica Ukrainy. – 2009. – 3. – P. 58 60. (Ukr.)
. 4
ISSN 1607-7970. . . 2011. 1 87
6. Lin Jackson, Bissonnette Marc R. A New Capacitive Proximity Probe Immune To Electrical Runout //
Canadian Machine Vibration Association, 1997 Annual Meeting – Toronto,Canada. – 3–5 November 1997. – P. 1–5.
www.vibrosystm.com/pdf/PCS_CMVA.PDF.
681.586.772
1, , .I. 2,
1. 2 ,
. , 56, -57, 03680,
,
. ,
, . -
. , . -
, ,
. ,
. ,
. . 6, . 4.
: , , , , .
A.S.Levytskyi1, A.I.Novik2
1, 2 Institute of Electrodynamics National Academy Science of Ukraine,
Peremogy, 56, Kyiv-57, 03680, Ukraine
Systematic error reduction of capacitive sensor of shaft beats due to deformation of active electrode
Capacitive sensor of radical shaft beats of huge electric machines which has an active scalene rectangle electrode has
been suggested. While measuring a shorter side of rectangle arranges perpendicular to longitudinal axis of shaft.
The calculation of sensor transfer function has been carried out. Analysis of the error caused by curvature of target
cylindrical surface has been performed. Also, it has been shown that the error depends only on the side dimension of
active electrode which is perpendicular to longitudinal axis of shaft.
Comparison of the error with the capacitive sensor error of shaft beats with an active rounded electrode having the
same area has been made. Also, it has been shown that the error of sensor with rectangular electrode is several times
smaller. References 6, figures 4.
Key words: hydrogenerators, shafts, radial run-out, capacitive sensors, error measurement
07.06.2010
Received 07.06.2010
http://www.vibrosystm.com/pdf/PCS_CMVA.PDF.
|
| id | techned_org_ua-article-1416 |
| institution | Technical Electrodynamics |
| keywords_txt_mv | keywords |
| language | Ukrainian |
| last_indexed | 2026-06-16T01:26:29Z |
| publishDate | 2010 |
| publisher | Інститут електродинаміки НАН України, Київ |
| record_format | ojs |
| resource_txt_mv | technedorgua/f1/8b7e4d03b606947e8a00769f6af8faf1.pdf |
| spelling | techned_org_ua-article-14162023-01-28T16:55:22Z SYSTEMATIC ERROR REDUCTION OF CAPACITIVE SENSOR OF SHAFT BEATS DUE TO DEFORMATION OF ACTIVE ELECTRODE УМЕНЬШЕНИЕ СИСТЕМАТИЧЕСКОЙ ПОГРЕШНОСТИ ЕМКОСТНОГО ДАТЧИКА БИЕНИЙ ВАЛА ЗА СЧЕТ ИЗМЕНЕНИЯ ФОРМЫ АКТИВНОГО ЭЛЕКТРОДА Левицкий, А.С. Новик, А.И. hydrogenerators shafts radial run-out capacitive sensors error measurement гидрогенераторы валы радиальное биение емкостные датчики погрешность измерения Capacitive sensor of radical shaft beats of huge electric machines which has an active scalene rectangle electrode has been suggested. While measuring a shorter side of rectangle arranges perpendicular to longitudinal axis of shaft. The calculation of sensor transfer function has been carried out. Analysis of the error caused by curvature of target cylindrical surface has been performed. Also, it has been shown that the error depends only on the side dimension of active electrode which is perpendicular to longitudinal axis of shaft. Comparison of the error with the capacitive sensor error of shaft beats with an active rounded electrode having the same area has been made. Also, it has been shown that the error of sensor with rectangular electrode is several times smaller. References 6, figures 4. Предложен емкостный датчик радиальных биений вала крупных электрических машин, у которого активный электрод выполнен в виде неравностороннего прямоугольника При измерении более короткая сторона прямоугольника располагается перпендикулярно продольной оси вала Проведен расчет функции преобразования датчика Выполнен анализ погрешности, обусловленной кривизной контролируемой цилиндрической поверхности Показано, что погрешность зависит только от размера стороны активного электрода, перпендикулярной продольной оси вала. Проведено сравнение погрешности с погрешностью емкостного датчика биений с активным электродом круглой формы и имеющего такую же площадь. Показано, что погрешность датчика с прямоугольным электродом в несколько раз меньше. Библ. 6, рис. 4. Інститут електродинаміки НАН України, Київ 2010-12-23 Article Article application/pdf https://techned.org.ua/index.php/techned/article/view/1416 Tekhnichna Elektrodynamika; No. 1 (2011): TEKHNICHNA ELEKTRODYNAMIKA; 083 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; № 1 (2011): ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; 083 2218-1903 1607-7970 uk https://techned.org.ua/index.php/techned/article/view/1416/1298 Авторське право (c) 2023 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА https://creativecommons.org/licenses/by-nc-nd/4.0 |
| spellingShingle | гидрогенераторы валы радиальное биение емкостные датчики погрешность измерения Левицкий, А.С. Новик, А.И. УМЕНЬШЕНИЕ СИСТЕМАТИЧЕСКОЙ ПОГРЕШНОСТИ ЕМКОСТНОГО ДАТЧИКА БИЕНИЙ ВАЛА ЗА СЧЕТ ИЗМЕНЕНИЯ ФОРМЫ АКТИВНОГО ЭЛЕКТРОДА |
| title | УМЕНЬШЕНИЕ СИСТЕМАТИЧЕСКОЙ ПОГРЕШНОСТИ ЕМКОСТНОГО ДАТЧИКА БИЕНИЙ ВАЛА ЗА СЧЕТ ИЗМЕНЕНИЯ ФОРМЫ АКТИВНОГО ЭЛЕКТРОДА |
| title_alt | SYSTEMATIC ERROR REDUCTION OF CAPACITIVE SENSOR OF SHAFT BEATS DUE TO DEFORMATION OF ACTIVE ELECTRODE |
| title_full | УМЕНЬШЕНИЕ СИСТЕМАТИЧЕСКОЙ ПОГРЕШНОСТИ ЕМКОСТНОГО ДАТЧИКА БИЕНИЙ ВАЛА ЗА СЧЕТ ИЗМЕНЕНИЯ ФОРМЫ АКТИВНОГО ЭЛЕКТРОДА |
| title_fullStr | УМЕНЬШЕНИЕ СИСТЕМАТИЧЕСКОЙ ПОГРЕШНОСТИ ЕМКОСТНОГО ДАТЧИКА БИЕНИЙ ВАЛА ЗА СЧЕТ ИЗМЕНЕНИЯ ФОРМЫ АКТИВНОГО ЭЛЕКТРОДА |
| title_full_unstemmed | УМЕНЬШЕНИЕ СИСТЕМАТИЧЕСКОЙ ПОГРЕШНОСТИ ЕМКОСТНОГО ДАТЧИКА БИЕНИЙ ВАЛА ЗА СЧЕТ ИЗМЕНЕНИЯ ФОРМЫ АКТИВНОГО ЭЛЕКТРОДА |
| title_short | УМЕНЬШЕНИЕ СИСТЕМАТИЧЕСКОЙ ПОГРЕШНОСТИ ЕМКОСТНОГО ДАТЧИКА БИЕНИЙ ВАЛА ЗА СЧЕТ ИЗМЕНЕНИЯ ФОРМЫ АКТИВНОГО ЭЛЕКТРОДА |
| title_sort | уменьшение систематической погрешности емкостного датчика биений вала за счет изменения формы активного электрода |
| topic | гидрогенераторы валы радиальное биение емкостные датчики погрешность измерения |
| topic_facet | hydrogenerators shafts radial run-out capacitive sensors error measurement гидрогенераторы валы радиальное биение емкостные датчики погрешность измерения |
| url | https://techned.org.ua/index.php/techned/article/view/1416 |
| work_keys_str_mv | AT levickijas systematicerrorreductionofcapacitivesensorofshaftbeatsduetodeformationofactiveelectrode AT novikai systematicerrorreductionofcapacitivesensorofshaftbeatsduetodeformationofactiveelectrode AT levickijas umenʹšeniesistematičeskojpogrešnostiemkostnogodatčikabienijvalazasčetizmeneniâformyaktivnogoélektroda AT novikai umenʹšeniesistematičeskojpogrešnostiemkostnogodatčikabienijvalazasčetizmeneniâformyaktivnogoélektroda |