ДИСТАНЦІЙНИЙ ЗАХИСТ В ЕЛЕКТРОЕНЕРГЕТИЧНИХ СИСТЕМАХ З РОЗПОДІЛЕНИМИ ДЖЕРЕЛАМИ ГЕНЕРАЦІЇ ПРИ НЕСИМЕТРИЧНИХ КОРОТКИХ ЗАМИКАННЯХ

In the post-war restoration of Ukraine's energy sector, the role of remote protection (RP) and emergency automation (EA) is being transformed from supporting current performance to creating the foundation for a high-tech, decentralized and sustainable system "Grids of the Future&qu...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2026
Автори: Денисюк , С.П., Омельчук, А.О., Дерев’янко, Д.Г., Заколодяжний, В.В.
Формат: Стаття
Опубліковано: Інститут електродинаміки НАН України, Київ 2026
Теми:
Онлайн доступ:https://techned.org.ua/index.php/techned/article/view/1826
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Technical Electrodynamics

Репозитарії

Technical Electrodynamics
_version_ 1869653467520303104
author Денисюк , С.П.
Омельчук, А.О.
Дерев’янко, Д.Г.
Заколодяжний, В.В.
author_facet Денисюк , С.П.
Омельчук, А.О.
Дерев’янко, Д.Г.
Заколодяжний, В.В.
author_institution_txt_mv [ { "author": "С.П. Денисюк ", "institution": "Інститут електродинаміки НАН України, пр. Берестейський, 56, Київ, 03057, Україна" }, { "author": "А.О. Омельчук", "institution": "Національний технічний університет України “Київський політехнічний інститут імені Ігоря Сікорського”, пр. Берестейський, 37, Київ, 03056, Україна" }, { "author": "Д.Г. Дерев’янко", "institution": "Національний технічний університет України “Київський політехнічний інститут імені Ігоря Сікорського”, пр. Берестейський, 37, Київ, 03056, Україна" }, { "author": "В.В. Заколодяжний", "institution": "Національний технічний університет України “Київський політехнічний інститут імені Ігоря Сікорського”, пр. Берестейський, 37, Київ, 03056, Україна" } ]
author_sort Денисюк , С.П.
baseUrl_str https://techned.org.ua/index.php/techned/oai
collection OJS
datestamp_date 2026-07-02T07:39:56Z
description In the post-war restoration of Ukraine's energy sector, the role of remote protection (RP) and emergency automation (EA) is being transformed from supporting current performance to creating the foundation for a high-tech, decentralized and sustainable system "Grids of the Future". A promising role in the post-war restoration will belong to the integration of DGS with energy storage and the implementation of adaptive protection systems to increase the economic efficiency of automation of both local and central electrical system modes by reducing the duration of outages and, accordingly, reducing losses to consumers and the energy supply company. The widespread introduction of distributed generation sources (DGS) in electrical networks in the form of solar, wind, and in recent periods, cogeneration plants, turns them into decentralized electric power systems (EPS with DGS), which in turn requires the improvement of their relay protection systems and automatic control systems for their operating modes. The dispersion of such sources and the uncertainty and instability of their generation schedules create additional requirements for the operation of emergency automation in these distribution networks. The article presents the results of a study of the parameters of remote protection with a time delay dependent on the short-circuit circuit resistance for branched distribution lines with redundancy and distributed generation sources under probable two-phase short circuits, taking into account the parameters and operating modes of these lines. The characteristics of the remote protection devices of these lines are obtained, recommended for their adjustment. The conditions under which it is advisable to use remote protection schemes with control of line voltages and phase current differences are determined, but to protect such lines from double ground faults, separate protection should be used, and in its absence, the connection of the main protection for line voltages and phase currents. The efficiency of the full-impedance remote protection operation should be assessed by the maximum length of the electric arc, which is determined by the voltage drop at the point of installation of the protection at the corresponding protection sensitivity coefficient. The method of studying the parameters and operating modes of remote protection of networks with an isolated neutral is used, and the results obtained are recommended for use in the formation of decentralized electric power systems with DGS in the post-war period of development, taking into account today's challenges and the long-term plan. References 20, Figures 3, Table 1.
first_indexed 2026-07-02T01:01:59Z
format Article
fulltext
id techned_org_ua-article-1826
institution Technical Electrodynamics
keywords_txt_mv keywords
last_indexed 2026-07-03T01:01:32Z
publishDate 2026
publisher Інститут електродинаміки НАН України, Київ
record_format ojs
resource_txt_mv
spelling techned_org_ua-article-18262026-07-02T07:39:56Z RESEARCH ON THE SENSITIVITY OF DISTANCE PROTECTION OF RESERVED POWER TRANSMISSION LINES TO UNSYMMETRICAL SHORT CIRCUITS ДИСТАНЦІЙНИЙ ЗАХИСТ В ЕЛЕКТРОЕНЕРГЕТИЧНИХ СИСТЕМАХ З РОЗПОДІЛЕНИМИ ДЖЕРЕЛАМИ ГЕНЕРАЦІЇ ПРИ НЕСИМЕТРИЧНИХ КОРОТКИХ ЗАМИКАННЯХ Денисюк , С.П. Омельчук, А.О. Дерев’янко, Д.Г. Заколодяжний, В.В. distributed generation sources redundant power transmission lines remote relay protection electric arc homogeneous sensitivity розподілені джерела генерації резервовані лінії електропередавання дистанційний релейний захист електрична дуга чутливість In the post-war restoration of Ukraine's energy sector, the role of remote protection (RP) and emergency automation (EA) is being transformed from supporting current performance to creating the foundation for a high-tech, decentralized and sustainable system "Grids of the Future". A promising role in the post-war restoration will belong to the integration of DGS with energy storage and the implementation of adaptive protection systems to increase the economic efficiency of automation of both local and central electrical system modes by reducing the duration of outages and, accordingly, reducing losses to consumers and the energy supply company. The widespread introduction of distributed generation sources (DGS) in electrical networks in the form of solar, wind, and in recent periods, cogeneration plants, turns them into decentralized electric power systems (EPS with DGS), which in turn requires the improvement of their relay protection systems and automatic control systems for their operating modes. The dispersion of such sources and the uncertainty and instability of their generation schedules create additional requirements for the operation of emergency automation in these distribution networks. The article presents the results of a study of the parameters of remote protection with a time delay dependent on the short-circuit circuit resistance for branched distribution lines with redundancy and distributed generation sources under probable two-phase short circuits, taking into account the parameters and operating modes of these lines. The characteristics of the remote protection devices of these lines are obtained, recommended for their adjustment. The conditions under which it is advisable to use remote protection schemes with control of line voltages and phase current differences are determined, but to protect such lines from double ground faults, separate protection should be used, and in its absence, the connection of the main protection for line voltages and phase currents. The efficiency of the full-impedance remote protection operation should be assessed by the maximum length of the electric arc, which is determined by the voltage drop at the point of installation of the protection at the corresponding protection sensitivity coefficient. The method of studying the parameters and operating modes of remote protection of networks with an isolated neutral is used, and the results obtained are recommended for use in the formation of decentralized electric power systems with DGS in the post-war period of development, taking into account today's challenges and the long-term plan. References 20, Figures 3, Table 1. У повоєнному відновленні енергетики України роль дистанційного захисту та протиаварійної автоматики трансформується з підтримки поточної працездатності у створення фундаменту для високотехнологічної, децентралізованої та стійкої системи «Grids of the Future». Перспективна роль у повоєнному відновленні належатиме інтеграції розподілених джерел генерації (РДГ) з накопичувачами енергії та впровадженні адаптивних систем захисту задля підвищення економічної ефективності автоматизації режимів як локальних, так і центральної електричної системи шляхом скорочення тривалості відключень і, відповідно, зменшення збитків споживачам та енергопостачальній компанії. Широке впровадження в електричних мережах розподілених джерел генерації у вигляді сонячних, вітрових, а в останні періоди й когенераційних установок, перетворює їх в децентралізовані електроенергетичні системи (ЕЕС з РДГ), що, в свою чергу, вимагає удосконалення систем їхнього релейного захисту та систем автоматичного керування режимами їхньої роботи. Розосередженість таких джерел, невизначеність та нестабільність графіків їхньої генерації створює додаткові вимоги й до роботи протиаварійної автоматики в цих розподільних мережах. У роботі наведено результати дослідження параметрів дистанційних захистів з залежною від опору кола короткого замикання витримкою часу для розгалужених розподільних ліній з резервуванням та розподіленими джерелами генерації за імовірних двофазних коротких замиканнях з урахуванням параметрів і режимів роботи цих ліній. Отримані характеристики налаштування пристроїв дистанційного захисту цих ліній рекомендовано для їхнього налагодження. Визначено умови, за яких доцільно застосовувати схеми дистанційного захисту з контролем лінійних напруг і різниці фазних струмів, але для захисту таких ліній від подвійних замикань на землю рекомендовано застосовувати окремий захист, а у разі його відсутності – приєднання основного захисту на лінійні напруги і фазні струми. Ефективність роботи дистанційного захисту повного опору доцільно оцінювати за максимальною довжиною електричної дуги, котра визначається зниженням напруги в місці встановлення захисту за відповідного коефіцієнта чутливості захисту. Використану методику дослідження параметрів і режимів роботи дистанційного захисту мереж з ізольованою нейтраллю та отримані результати рекомендується використовувати під час формування децентралізованих електроенергетичних систем з РДГ в повоєнний період розбудови з урахуванням сьогоднішніх викликів та перспективного плану. Бібл. 20, рис. 3, табл. 1. Інститут електродинаміки НАН України, Київ 2026-07-01 Article Article https://techned.org.ua/index.php/techned/article/view/1826 Tekhnichna Elektrodynamika; No. 4 (2026): TEKHNICHNA ELEKTRODYNAMIKA; 057 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; № 4 (2026): ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; 057 2218-1903 1607-7970 Авторське право (c) 2026 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА https://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle розподілені джерела генерації
резервовані лінії електропередавання
дистанційний релейний захист
електрична дуга
чутливість
Денисюк , С.П.
Омельчук, А.О.
Дерев’янко, Д.Г.
Заколодяжний, В.В.
ДИСТАНЦІЙНИЙ ЗАХИСТ В ЕЛЕКТРОЕНЕРГЕТИЧНИХ СИСТЕМАХ З РОЗПОДІЛЕНИМИ ДЖЕРЕЛАМИ ГЕНЕРАЦІЇ ПРИ НЕСИМЕТРИЧНИХ КОРОТКИХ ЗАМИКАННЯХ
title ДИСТАНЦІЙНИЙ ЗАХИСТ В ЕЛЕКТРОЕНЕРГЕТИЧНИХ СИСТЕМАХ З РОЗПОДІЛЕНИМИ ДЖЕРЕЛАМИ ГЕНЕРАЦІЇ ПРИ НЕСИМЕТРИЧНИХ КОРОТКИХ ЗАМИКАННЯХ
title_alt RESEARCH ON THE SENSITIVITY OF DISTANCE PROTECTION OF RESERVED POWER TRANSMISSION LINES TO UNSYMMETRICAL SHORT CIRCUITS
title_full ДИСТАНЦІЙНИЙ ЗАХИСТ В ЕЛЕКТРОЕНЕРГЕТИЧНИХ СИСТЕМАХ З РОЗПОДІЛЕНИМИ ДЖЕРЕЛАМИ ГЕНЕРАЦІЇ ПРИ НЕСИМЕТРИЧНИХ КОРОТКИХ ЗАМИКАННЯХ
title_fullStr ДИСТАНЦІЙНИЙ ЗАХИСТ В ЕЛЕКТРОЕНЕРГЕТИЧНИХ СИСТЕМАХ З РОЗПОДІЛЕНИМИ ДЖЕРЕЛАМИ ГЕНЕРАЦІЇ ПРИ НЕСИМЕТРИЧНИХ КОРОТКИХ ЗАМИКАННЯХ
title_full_unstemmed ДИСТАНЦІЙНИЙ ЗАХИСТ В ЕЛЕКТРОЕНЕРГЕТИЧНИХ СИСТЕМАХ З РОЗПОДІЛЕНИМИ ДЖЕРЕЛАМИ ГЕНЕРАЦІЇ ПРИ НЕСИМЕТРИЧНИХ КОРОТКИХ ЗАМИКАННЯХ
title_short ДИСТАНЦІЙНИЙ ЗАХИСТ В ЕЛЕКТРОЕНЕРГЕТИЧНИХ СИСТЕМАХ З РОЗПОДІЛЕНИМИ ДЖЕРЕЛАМИ ГЕНЕРАЦІЇ ПРИ НЕСИМЕТРИЧНИХ КОРОТКИХ ЗАМИКАННЯХ
title_sort дистанційний захист в електроенергетичних системах з розподіленими джерелами генерації при несиметричних коротких замиканнях
topic розподілені джерела генерації
резервовані лінії електропередавання
дистанційний релейний захист
електрична дуга
чутливість
topic_facet distributed generation sources
redundant power transmission lines
remote relay protection
electric arc
homogeneous sensitivity
розподілені джерела генерації
резервовані лінії електропередавання
дистанційний релейний захист
електрична дуга
чутливість
url https://techned.org.ua/index.php/techned/article/view/1826
work_keys_str_mv AT denisûksp researchonthesensitivityofdistanceprotectionofreservedpowertransmissionlinestounsymmetricalshortcircuits
AT omelʹčukao researchonthesensitivityofdistanceprotectionofreservedpowertransmissionlinestounsymmetricalshortcircuits
AT derevânkodg researchonthesensitivityofdistanceprotectionofreservedpowertransmissionlinestounsymmetricalshortcircuits
AT zakolodâžnijvv researchonthesensitivityofdistanceprotectionofreservedpowertransmissionlinestounsymmetricalshortcircuits
AT denisûksp distancíjnijzahistvelektroenergetičnihsistemahzrozpodílenimidžerelamigeneracííprinesimetričnihkorotkihzamikannâh
AT omelʹčukao distancíjnijzahistvelektroenergetičnihsistemahzrozpodílenimidžerelamigeneracííprinesimetričnihkorotkihzamikannâh
AT derevânkodg distancíjnijzahistvelektroenergetičnihsistemahzrozpodílenimidžerelamigeneracííprinesimetričnihkorotkihzamikannâh
AT zakolodâžnijvv distancíjnijzahistvelektroenergetičnihsistemahzrozpodílenimidžerelamigeneracííprinesimetričnihkorotkihzamikannâh