MODELING OF ELECTRICAL CHARACTERISTICS OF A SILICON PHOTOVOLTAIC MODULE EQUIPPED WITH A SOLAR RADIATION CONCENTRATOR
The purpose of this article is to analyze the electrical characteristics of a photovoltaic module with a solar radiation concentrator. The object of the study is a simple commercially available photovoltaic module with the simplest solar radiation concentrator without additional cooling systems, whi...
Збережено в:
| Дата: | 2025 |
|---|---|
| Автор: | |
| Формат: | Стаття |
| Мова: | Українська |
| Опубліковано: |
Institute of Renewable Energy National Academy of Sciences of Ukraine
2025
|
| Теми: | |
| Онлайн доступ: | https://ve.org.ua/index.php/journal/article/view/580 |
| Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
| Назва журналу: | Vidnovluvana energetika |
| Завантажити файл: | |
Репозитарії
Vidnovluvana energetika| _version_ | 1871104036678139904 |
|---|---|
| author | Kuznietsov , M. |
| author_facet | Kuznietsov , M. |
| author_institution_txt_mv | [
{
"author": "M. Kuznietsov ",
"institution": "Institute of Renewable Energy, NAS of Ukraine, Kyiv, Ukraine"
}
] |
| author_sort | Kuznietsov , M. |
| baseUrl_str | https://ve.org.ua/index.php/journal/oai |
| collection | OJS |
| datestamp_date | 2026-07-18T06:32:23Z |
| description | The purpose of this article is to analyze the electrical characteristics of a photovoltaic module with a solar radiation concentrator. The object of the study is a simple commercially available photovoltaic module with the simplest solar radiation concentrator without additional cooling systems, which makes this solution technically simple and commercially attractive. The task is to evaluate the technical feasibility of such a solution. The study provides comparative characteristics of the dependence of power on voltage and monthly electricity generation of the mentioned concentrator system compared to a traditional solution – a set of photovoltaic modules connected in series. To assess the impact of the concentrator itself on the characteristics of the module, a comparison with a certain idealized solution is also made. As a conclusion, the feasibility of solar energy concentrators with conventional photovoltaic modules is demonstrated, since despite a 35% drop in electricity generation per unit area, the cost of such a solution is expected to be lower, because one module with a concentrator will be able to generate as much energy as 8 modules without radiation concentration. Bibliography 14. |
| doi_str_mv | 10.36296/1819-8058.2025.4(83).136-145 |
| first_indexed | 2026-02-08T07:59:29Z |
| format | Article |
| fulltext |
136
Відновлювана енергетика. № 4/2025 | Сонячна енергетика
УДК 621.311.25 https://doi.org/10.36296/1819-8058.2025.4(83).136-145
МОДЕЛЮВАННЯ ЕЛЕКТРИЧНИХ ХАРАКТЕРИСТИК КРЕМНІЄВОГО ФОТОЕЛЕКТРИЧНОГО
МОДУЛЯ З КОНЦЕНТРАТОРОМ СОНЯЧНОГО ВИПРОМІНЮВАННЯ
Отримано 30 лист. 2025 р.; рекомендовано до публікації 09 груд. 2025 р.
Доступно онлайн 31 груд. 2025 р.
Кузнєцов М. М.
Автор для кореспонденції: Кузнєцов Микола,
e-mail: kuznietsov.m.m@gmail.com
Анотація. Метою роботи є аналіз електричних характеристик фотоелектричного модуля з концен-
тратором сонячної енергії. Об’єкт дослідження – простий фотоелектричний модуль з найпростішим
концентратором сонячної енергії без додаткових систем охолодження, що робить таке рішення тех-
нічно простим і комерційно привабливим. Задача роботи полягає в оцінці технічної доцільності такого
рішення. У роботі наводяться порівняльні характеристики залежності потужності від напруги та по-
місячної генерації електроенергії зазначеного рішення порівняно з традиційним рішенням – набором по-
слідовно включених фотоелектричних модулів. Для оцінки впливу самого концентратора на характе-
ристики модуля наведено також порівняння з певним ідеалізованим рішенням. Визначено доцільність
використання концентраторів сонячної енергії зі звичайними фотоелектричними модулями, оскільки
попри 35%-ве падіння генерації електроенергії з одиниці площі вартість такого рішення очікується мен-
шою: один модуль з концентратором передбачено генерує стільки ж енергії, скільки вісім модулів без
концентратора. Бібл.14.
Ключові слова: відновлювані джерела енергії, фотоелектрична станція, концентратор сонячного ви-
промінювання, прогноз генерації електроенергії.
Використані позначення та скорочення
ФЕМ – фотоелектричний модуль
PV – photovoltaic, фотоелектричний
MPPT – max power point tracker, пристрій для відслідко-
вування найбільшої потужності на вихідній характерис-
тиці ФЕМ і утримання цієї точки як робочої для системи
генерації енергії
Вступ
Технологія концентрації сонячного випромінювання по-
сідає вагоме місце в сонячній енергетиці. Водночас ця
технологія насамперед зосереджена на отриманні тер-
мальної енергії [1, 2] та комбінації термальної й фотое-
лектричної енергії [3, 4]. Менша увага приділяється ви-
ключно енергії фотоелектричній. При цьому перевага
віддається застосуванню «високоефективних» фотоеле-
ментів [4–7] та систем примусового охолодження [8].
Використанню доступних на ринку звичайних фотоеле-
ктричних модулів на базі однопереходового кристаліч-
ного кремнію з концентраторами сонячного випромі-
нювання приділено мало уваги. З огляду на вищу
вартість фотоелектричної енергії порівняно з енергією з
викопних джерел доцільно шукати технічного рішення
для зменшення ціни сонячних електростанцій. Викори-
стання концентрації сонячної енергії з існуючими коме-
рційно доступними фотоелектричними модулями
(ФЕМ) є цікавим рішенням, оскільки вартість простого
концентратора на базі лінзи Френеля, параболічного
дзеркала і т. п. за одиницю площі вбачається меншою,
ніж у фотоелектричного модуля.
Мета
Метою роботи є порівняльний аналіз електричних хара-
ктеристик типового фотоелектричного модуля з конце-
нтратором сонячного випромінювання і поля аналогіч-
них фотоелектричних модулів сумарною площею,
рівною площі апертури концентратора. У подальшому
це дасть змогу проводити техніко-економічні розраху-
нки доцільності таких систем. Як приклад ФЕМ взято мо-
дель A10Green Technology A10J-S72-175 номінальною
потужністю 175 Вт. Особливості конкретних типів соняч-
них концентраторів не розглядаються в цій роботі,
проте з огляду на ідею використання недорогого ФЕМ
оптичні характеристики концентратора вибрані такими,
що відповідають найпростішим їх видам – лінзі Френеля
та параболічному дзеркалу.
Розрахунок концентратора сонячного випроміню-
вання
Природним обмеженням для ФЕМ з концентратором
сонячної енергії є температура фотоелемента. Типовим
значенням максимальної допустимої температури екс-
плуатації для ФЕМ є 85 ⁰С.
канд. техн. наук.
https://orcid.org/0000-0002-0286-5652
Інститут відновлюваної енергетики НАН
України, м. Київ, Україна
137
Відновлювана енергетика. № 4/2025 | Сонячна енергетика
Для оцінки максимальної сонячної енергії для одинич-
ного фотоелектричного модуля використовується про-
ста лінійна апроксимація [9, 10]:
𝑇 = 𝑇𝑎 +
𝐺
𝐺𝑁𝑂𝐶𝑇
(𝑇𝑁𝑂𝐶𝑇 − 𝑇𝑎,𝑁𝑂𝐶𝑇) (1)
де T – температура ФЕМ (⁰С) за інтенсивності сонячної
радіації G (Вт/м2) та температури навколишнього сере-
довища Ta (⁰С); TNOCT – номінальна робоча температура
ФЕМ, що вказується виробником у специфікації до кон-
кретного ФЕМ; GNOCT = 800 Вт/м2 та Ta,NOCT = 20 ⁰ – зна-
чення інтенсивності сонячної радіації й температури,
відповідно, за так званих нормальних умов (nominal
terrestrial environment NTE).
Оптична ефективність концентратора на основі лінзи
Френеля та простого параболічного дзеркала становить
близько 70 % [7]. Існуючі технології дозволяють отри-
мати оптичну ефективність концентратора до 84–98 %
[7, 11], проте техніко-економічна доцільність таких рі-
шень для використання зі звичайними ФЕМ вбачається
сумнівною.
Вибір концентратора повинен враховувати сонячну ра-
діацію в місці експлуатації. У подальшому розгляда-
ються кліматичні умови для м. Київ в 2019 році, де мак-
симальне значення радіації становило 918 Вт/м2, а
найвища зафіксована температура – 35 ⁰0С [12]. Без за-
стосування примусового охолодження, як зазначено
вище, максимальна температура ФЕМ не повинна пере-
вищувати 85 ⁰С. Підставляючи у рівняння (1) типове зна-
чення температури TNOCT = 25 ⁰С, температуру навколи-
шнього середовища Ta = 35 ⁰С, можна отримати
максимальне значення сонячної радіації на поверхні
модуля Gmax, що не призведе до його перегріву:
85 = 35 +
𝐺𝑚𝑎𝑥
800
(25 − 20) → 𝐺𝑚𝑎𝑥 = 8000(Вт/м2) (2)
Оскільки це дослідження не фокусується на конструк-
тиві самого концентратора, з усього різноманіття його
параметрів важливими є коефіцієнт концентрації соняч-
ної енергії X, який вимірюється в кількості сонць [13], і
геометрична концентрація Cg [7]:
𝑋 =
𝐺𝑥
𝐺
, 𝐶𝑔 =
𝐴
𝑎
, (3)
де Gx – середня інтенсивність концентрованої сонячної
радіації, G – середнє значення сонячної радіації без за-
стосування концентратора, A – площа апертури концен-
тратора, a – площа ресівера (площа перетину потоку
концентрованого сонячного випромінювання).
Для наведених вище кліматичних умов і з урахуванням
співвідношення (2), а також оптичної ефективності кон-
центратора 0.7, коефіцієнт концентрації сонячної енергії
не повинен перевищувати X = 8000/918 = 8.71 (сонць), а
геометрична концентрація Cg = 8.71/0.7 = 12.44. Зна-
чення коефіцієнта концентрації сонячної енергії X = 8.71
відповідає системам низької концентрації, для яких під-
ходить звичайний кристалічний кремній як матеріал
фотоелемента [13]. Для спрощення подальшого порів-
няльного аналізу, виберемо концентратор з величиною
геометричної концентрації Cg = 12, тобто апертура кон-
центратора матиме таку саму площу, що й сумарна ак-
тивна (робоча) площа 12 таких самих ФЕМ без концент-
рації сонячної радіації.
Порівняння електричних характеристик одного ФЕМ з
концентратором і поля ФЕМ
Далі наведено порівняльний аналіз електричних харак-
теристик та генерації електроенергії одного ФЕМ з кон-
центратором зі значенням Cg = 12 й оптичною ефектив-
ністю 0.7, і поля з 12 аналогічних ФЕМ. Активна площа
обох рішень при цьому буде однакова. Щодо підклю-
чення, то 12 ФЕМ можна об’єднати різними способами,
які впливатимуть насамперед на номінальні значення
напруг і струмів, проте сумарна номінальна потужність
буде однаковою. Виберемо послідовне підключення як
найрозповсюдженіше. Нижче наведені сімейства хара-
ктеристик залежності потужності від напруги зазначе-
них рішень для різних значень сонячної радіації й тем-
ператури. Як ФЕМ розглядався A10Green Technology
A10J-S72-175 номінальною потужністю 175 Вт. Характе-
ристики отримані симуляцією в середовищі Matlab
Simulink. Для моделювання ФЕМ використаний об’єкт
«PV Array» з бібліотеки «Simscape». Модель сонячної ус-
тановки враховує залежність температури модуля від
радіації відповідно до рівняння (1). Концентратор соня-
чного випромінювання приймався з величиною геомет-
ричної концентрації Cg = 12 і оптичною ефективністю 0,7,
тобто коефіцієнтом концентрації (кількість сонць) X =
8.4.
Як видно на рис. 1 і рис. 2, загалом максимальна потуж-
ність поля з 12 ФЕМ буде приблизно вдвічі більша за по-
тужність одного ФЕМ з концентратором. Водночас що
нижча температура й освітленість, то менша різниця
між потужностями одного модуля з концентратором і
поля ФЕМ. Це пояснюється як оптичними втратами в
концентраторі, так і погіршенням характеристик ФЕМ за
вищої температури. Для оцінки втрат на рис. 3 наведено
характеристики потужності ФЕМ з концентратором з оп-
тичною ефективністю в 0.95, що відповідає найефектив-
нішим існуючим рішенням [7, 11], та застосуванням пе-
вної системи охолодження, що забезпечує температуру
модуля з концентратором таку саму, як в аналогічного
модуля без концентратора за однакового рівня освіт-
лення і температури навколишнього середовища. Мо-
жна помітити, що характеристики потужності такої уста-
новки суттєво кращі, ніж у попередньо розглянутого
концентратора, проте все-таки поступаються полю ФЕМ
за високої освітленості й близькі до поля ФЕМ за низької
освітленості.
Також варто відзначити меншу крутизну характеристик
ФЕМ з концентратором у точці максимальної потужно-
сті, що знижує вимоги до точності MPPT трекера (max
power point tracking – відслідковування точки макси-
мально потужності) і потенційно зменшує втрати через
неоптимальне визначення робочої точки.
138
Відновлювана енергетика. № 4/2025 | Сонячна енергетика
а б
Рис. 1. Залежність потужності від напруги для: а – ФЕМ з концентратором; б – 12 послідовно об’єднаних
ФЕМ за температури 25 0С і величини сонячної радіації від 100 до 1000 Вт/м2
а б
Рис. 2. Залежність потужності від напруги для: а – ФЕМ з концентратором; б – 12 послідовно об’єднаних
ФЕМ за величини сонячної радіації 800 Вт/м2 і температури навколишнього середовища від –30 до 30 0С
а б
Рис. 3. Залежність потужності від напруги для ФЕМ з концентратором оптичною ефективністю 0.95 і
системою охолодження ФЕМ, якщо: а – температур 25 0С і величина сонячної радіації від 100 до
1000 Вт/м2; б – величина сонячної радіації 800 Вт/м2 і температура навколишнього середовища від –30 до
30 0С
139
Відновлювана енергетика. № 4/2025 | Сонячна енергетика
Порівняння виробітки електроенергії одного ФЕМ з
концентратором і поля ФЕМ
Для порівняльної оцінки можливостей генерації електрое-
нергії одного ФЕМ з концентратором і поля ФЕМ прове-
дена симуляція річної виробітки електроенергії відповідно
до способу, описаного в [14]. Порівнювались характерис-
тики: 1) ФЕМ з концентратором з величиною геометричної
концентрації Cg = 12 і оптичною ефективністю 0.7 (X = 8.4
сонць) та без системи охолодження, так званий низькое-
фективний концентратор; 2) ФЕМ з концентратором з ве-
личиною геометричної концентрації Cg = 12 і оптичною
ефективністю 0.95 (X = 11.4 сонць) та системою охоло-
дження, що нівелює вплив підвищеної сонячної радіації на
ФЕМ, так званий високоефективний концентратор; 3) поле
з 12 послідовно об’єднаних ФЕМ. Модель ФЕМ відповідає
A10Green Technology A10J-S72-175. Кліматичні дані для си-
муляції отримані з [12]: погодинні значення прямої соняч-
ної радіації на горизонтальну поверхню та температури по-
вітря для географічних координат м. Київ за 2019 рік.
Результати зведені до таблиці.
Таблиця. Річний виробіток електроенергії полем з 12 ФЕМ, ФЕМ з «низькоефективним» концентратором та ФЕМ
з «високоефективним» концентратором і системою охолодження
12 ФЕМ ФЕМ з «низькоефектив-
ним» концентратором
ФЕМ з «високооефектив-
ним» концентратором
Місяць Світ-
лий час
доби, г
Середня
темпера-
тура, С°
Середня
сонячна
радіація,
Вт/м2
Місячна
генера-
ція, кВт·г
Місячна ге-
нерація,
кВт·г
Частка
генерації
відносно
12 ФЕМ
Місячна ге-
нерація,
кВт·г
Частка гене-
рації відно-
сно 12 ФЕМ
Січень 302 -7 107 73.4 52.8 72 % 72.8 99 %
Лютий 304 -2 182 124.9 86.7 69 % 120.1 96 %
Березень 395 5 236 206.6 139.6 68 % 193.8 94 %
Квітень 439 11 310 293.6 190.8 65 % 266.2 91%
Травень 496 18 328 341.6 219.3 64 % 307.3 90%
Червень 536 24 382 419.9 260.7 62 % 366.4 87%
Липень 518 22 393 422.9 260.7 62 % 366.8 87 %
Серпень 479 23 380 375.8 233.4 62 % 328.2 87 %
Вересень 408 18 306 261.9 170.4 65 % 238.0 91 %
Жовтень 362 13 232 178.6 121.1 68 % 168.6 94 %
Листопад 300 5 135 87.9 62.7 71 % 86.7 99 %
Грудень 269 2 87 50.9 37.1 73 % 51.2 101 %
Річна генерація, кВт·г 2837.9 1835.4 65 % 2566.2 90 %
Як видно в таблиці, з розрахунку на річну генерацію еле-
ктроенергії один модуль з величиною геометричної
концентрації Cg = 12 виробить лише 65 % енергії, яку мо-
жна отримати з 12 аналогічних модулів, тоді як з ідеаль-
ним концентратором з охолодженням – 90 %. Водночас
що нижчі температура навколишнього середовища і со-
нячна радіація, то вища ефективність модуля з концент-
ратором. Можна оцінити, що модуль зі звичайним кон-
центратором згенерує стільки ж енергії, стільки і вісім
аналогічних модулів без концентрації сонячної енергії,
тобто генерація з одиниці активної площі установки з
простим концентратором без додаткових систем охоло-
дження буде приблизно в 1,5 раза нижчою, ніж з поля
ФЕМ аналогічної сумарної активної площі модулів. Фі-
нансові оцінки наразі не розглядаються, проте з огляду
на те, що в моделюванні прийнятий простий концентра-
тор без додаткових систем охолодження, можна вва-
жати, що за превалювання питання собівартості устано-
вки над питанням доступної площі таке рішення може
видатись раціональним.
Висновки
Використання звичайного комерційного фотоелектрич-
ного модуля з сонячним концентратором оптичною
ефективністю близько 0.7 і величиною геометричної
концентрації 12 дозволяє отримати генерацію, зіставну
з генерацією восьми аналогічних ФЕМ без концентра-
тора, не потребує системи охолодження, і має площу
апертури, рівну площі 12 аналогічних фотоелектричних
модулів. Тобто генерація електроенергії з одиниці
площі зменшується приблизно на 35 %, проте очікується
істотно менша вартість установки через відносну деше-
визну концентратора. Також менша крутизна вихідних
характеристик ФЕМ з концентратором знижує вимоги
до MPPT та втрати потужності через похибку визначення
точки максимальної потужності. У разі використання
концентратора з оптичною ефективністю на рівні кра-
щих досягнень сучасної технології й застосування сис-
тем охолодження для пониження температури ФЕМ
отримане значення генерації електроенергії лише на
10 % менше, ніж з множини фотоелектричних модулів.
Проте комерційну доцільність такого рішення оцінити
важко через складність концентратора і потребу в сис-
темі охолодження.
140
Відновлювана енергетика. № 4/2025 | Сонячна енергетика
ПОСИЛАННЯ
1. Ejaz A., Babar H., Ali H. M., J amil F., Janjua M. M., Fattah
I. M. R., Said Z., Li C. Concentrated photovoltaics as light
harvesters: Outlook, recent progress, and challenges.
Sustainable Energy Technologies and Assessments. Vol-
ume 46, August 2021, 101199. DOI:
https://doi.org/10.1016/j.seta.2021.101199
2. Xiao J., Wei X., Lu Z., Yu W., Wu H. A review of available
methods for surface shape measurement of solar con-
centrator in solar thermal power applications. Renewa-
ble and Sustainable Energy Reviews. Volume 16, Issue
5, June 2012, Pp. 2539–2544. DOI:
https://doi.org/10.1016/j.rser.2012.01.063
3. Ceylan I., Gürel A.E., Ergün A., Tabak A. Performance
analysis of a concentrated photovoltaic and thermal
system. Solar Energy. Volume 129, May 2016, Pp. 217–
223. DOI:
https://doi.org/10.1016/j.solener.2016.02.010
4. Cameron W. J., Reddy K. S., Mallick T. K. Review of high
concentration photovoltaic thermal hybrid systems for
highly efficient energy cogeneration. Renewable and
Sustainable Energy Reviews. Volume 163, July 022,
112512. DOI:
https://doi.org/10.1016/j.rser.2022.112512
5. Zubi G., J.L., Fracastoro G. V. High concentration photo-
voltaic systems applying III–V cells. Renewable and Sus-
tainable Energy Reviews. Volume 13, Issue 9, December
2009, Pp. 2645–652. DOI:
https://doi.org/10.1016/j.rser.2009.07.002
6. Solanki C. S., Sangani C. S., Gunashekar D., Antony G.
Enhanced heat dissipation of V-trough PV modules for
better performance. Solar Energy Materials and Solar
Cells. Volume 92, Issue 12, December 2008, Pp. 1634–
1638. DOI: https://doi.org/10.1016/j.sol
mat.2008.07.022
7. Iqbal W., Ullah I., Shin S. Optical Developments in Con-
centrator Photovoltaic Systems—A Review. Sustainabil-
ity. 2023, Volume 15, Issue 13, 10554. DOI:
https://doi.org/10.3390/su151310554
8. Jakhar S., Soni M. S., Gakkhar N. Historical and recent
development of concentrating photovoltaic cooling
technologies. Renewable and Sustainable Energy Re-
views. Volume 60, July 2016, Pp. 41–59. DOI:
https://doi.org/10.1016/j.rser.2016.01.083
9. Salilih E. M., Birhane Y. T. Modeling and Analysis of
Photo-Voltaic Solar Panel under Constant Electric Load.
Journal of Renewable Energy. Volume 2019, Article ID
9639480, 10 pages. DOI:
https://doi.org/10.1155/2019/9639480
10. Ghosh S. M., Shawon M. H., Rahman A., Abdullah R.
Modeling of PV Array and Analysis of Different Parame-
ters. International Journal of Advancements in Research
& Technology, Volume 2, Issue 5, May-2013. ISSN 2278-
7763. Pp. 358–363.
11. Li Y., A Study on the Optical Efficiency of Solar Concen-
trators Based on Ray Tracing Method. Highlights in Sci-
ence, Engineering and Technology. 2024. Volume 83.
Pp. 33–42. DOI: https://doi.org/10.54097/nz27b785
12. https://www.renewables.ninja/
13. Khamooshi M., Salati H., Egelioglu F., Faghiri A. H., Tar-
abishi J., Babadi S. A Review of Solar Photovoltaic Con-
centrators. International Journal of Photoenergy
(Hindawi). Volume 2014, Article ID 958521, 17 p. DOI:
http://dx.doi.org/10.1155/2014/958521
14. Кузнєцов М. М. Cпрощення електричних моделей
фотоелектричного модуля в задачах прогнозування
генерації електроенергії. Відновлювана енергетика.
2025. № 2. С. 126–132.
DOI:https://doi.org/10.36296/1819-
8058.2025.2(81).126-132
https://www.sciencedirect.com/author/6507310480/jose-luis-bernal-agustin
141
Відновлювана енергетика. № 4/2025 | Сонячна енергетика
UDС 621.311.25 https://doi.org/10.36296/1819-8058.2025.4(83).136-145
MODELING OF ELECTRICAL CHARACTERISTICS OF A SILICON PHOTOVOLTAIC MODULE EQUIPPED
WITH A SOLAR RADIATION CONCENTRATOR
Received Nov. 30, 2025; accepted Dec. 09, 2025
Available online Dec. 31, 2025
Kuznietsov M.
Author for correspondence: Kuznietsov Mykola,
e-mail: kuznietsov.m.m@gmail.com
Abstract. The purpose of this article is to analyze the electrical characteristics of a photovoltaic module with a
solar radiation concentrator. The object of the study is a simple commercially available photovoltaic module with
the simplest solar radiation concentrator without additional cooling systems, which makes this solution technically
simple and commercially attractive. The task is to evaluate the technical feasibility of such a solution. The study
provides comparative characteristics of the dependence of power on voltage and monthly electricity generation
of the mentioned concentrator system compared to a traditional solution – a set of photovoltaic modules
connected in series. To assess the impact of the concentrator itself on the characteristics of the module, a
comparison with a certain idealized solution is also made. As a conclusion, the feasibility of solar energy
concentrators with conventional photovoltaic modules is demonstrated, since despite a 35% drop in electricity
generation per unit area, the cost of such a solution is expected to be lower, because one module with a
concentrator will be able to generate as much energy as 8 modules without radiation concentration. Bibliography
14.
Keywords: renewable energy sources, solar power plant, solar radiation concentrator, electricity generation
forecast.
List of symbols and abbreviations used
PV module – photovoltaic module
MPPT – max power point tracker
Introduction
Concentrated solar power (CSP) technologies occupy a sig-
nificant position within the broader field of solar energy.
Nevertheless, these technologies have been primarily ori-
ented toward the generation of thermal energy [1, 2] and
hybrid thermal–photovoltaic systems [3, 4], while substan-
tially less attention has been devoted to purely photovol-
taic applications. In such cases, preference is typically given
to the implementation of high-efficiency solar cells [4–7] in
combination with forced cooling systems [8]. The use of
commercially available, standard single-junction crystalline
silicon photovoltaic modules equipped with solar radiation
concentrators has received comparatively limited consider-
ation. Given that the cost of photovoltaic electricity re-
mains higher than that derived from fossil fuels, it is in-
creasingly important to identify technical solutions capable
of reducing the capital cost of photovoltaic power plants.
Employing solar concentration in conjunction with existing
commercially available photovoltaic (PV) modules repre-
sents a promising pathway, as the cost per unit area of sim-
ple optical concentrators – such as Fresnel lenses or para-
bolic concentrators – appears to be lower than that of the
PV modules themselves.
Objective
The objective of this study is to conduct a comparative anal-
ysis of the electrical characteristics of a typical photovoltaic
module equipped with a solar radiation concentrator and
those of an array of analogous photovoltaic modules whose
total area is equivalent to the aperture area of the concen-
trator. This comparison will subsequently enable techno-
economic assessments of the feasibility of such systems. As
a representative PV module, the A10Green Technology
A10J-S72-175 model with a nominal power of 175 W is se-
lected. The investigation of the specific design features of
individual types of solar concentrators lies beyond the
scope of this work; however, given the concept of using a
low-cost photovoltaic module, the optical characteristics of
the concentrator are chosen to correspond to the simplest
available configurations – namely, a Fresnel lens or a para-
bolic concentrator.
Calculation of the Solar Radiation Concentrator
A natural limitation for a PV module operating with a solar
concentrator is the temperature of the PV cell. A typical
maximum operating temperature for such modules is 85 °C.
To estimate the maximum solar radiation for a single
Ph.D.
https://orcid.org/0000-0002-0286-5652
Institute of Renewable Energy, NAS of
Ukraine, Kyiv, Ukraine
142
Відновлювана енергетика. № 4/2025 | Сонячна енергетика
photovoltaic module, a simple linear approximation is used
[9,10]:
𝑇 = 𝑇𝑎 +
𝐺
𝐺𝑁𝑂𝐶𝑇
(𝑇𝑁𝑂𝐶𝑇 − 𝑇𝑎,𝑁𝑂𝐶𝑇) (1)
where T is the module temperature (⁰С) at solar irradiance
G (W/m2) and ambient temperature Ta (⁰С); TNOCT is the
nominal operating cell temperature specified by the manu-
facturer; GNOCT = 800 W/m2 and Ta,NOCT = 20 ⁰С correspond
to the nominal terrestrial environment (NTE) conditions.
The optical efficiency of concentrators based on Fresnel
lenses or a simple parabolic concentrator is approximately
70% [7]. Although existing technologies can achieve con-
centrator optical efficiencies of 84 – 98% [7, 11], their
techno-economic suitability for use with conventional pho-
tovoltaic modules appears questionable.
The selection of a concentrator must consider the local so-
lar irradiance at the installation site. In this study, the cli-
matic conditions of Kyiv city in 2019 are used: the maximum
recorded irradiance was 918 W/m2, and the highest ambi-
ent temperature reached 35 ⁰С [12]. As noted above, with-
out forced cooling, the module temperature must not ex-
ceed 85 ⁰С. Substituting a typical value of TNOCT = 25 0С and
Ta = 35 0С into Equation (1), the maximum permissible irra-
diance Gmax on the module surface that does not lead to
overheating is obtained:
85 = 35 +
𝐺𝑚𝑎𝑥
800
(25 − 20) → 𝐺𝑚𝑎𝑥 = 8000(𝑊/𝑚2) (2)
Since this work does not focus on concentrator design de-
tails, only two parameters are treated as essential: the solar
concentration ratio X, expressed in “suns” [13], and the ge-
ometric concentration ratio Cg [7]:
𝑋 =
𝐺𝑥
𝐺
, 𝐶𝑔 =
𝐴
𝑎
, (3)
where Gx is the average concentrated irradiance, G is the
average non-concentrated irradiance, A is the concentrator
aperture area, and a is the receiver area (the cross-section
of the concentrated radiation beam).
For the climatic conditions described above and consider-
ing Equation (2) and the concentrator’s optical efficiency of
0.7, the concentration ratio must not exceed
X=8000/918=8.71 suns, and the corresponding geometric
concentration ratio should not exceed Cg = 8.71/0.7 =
12.44. A concentration ratio of X = 8.71 falls within the
range of low-concentration photovoltaic systems, for which
standard crystalline silicon solar cells are suitable [13]. To
simplify the subsequent comparative analysis, a concentra-
tor with a geometric concentration ratio of Cg = 12 is se-
lected, meaning that the concentrator aperture area equals
the total active area of twelve identical photovoltaic mod-
ules operating without concentration.
Comparison of the Electrical Characteristics of a Single PV
Module with a Concentrator and an Array of PV Modules
A comparative analysis is presented below for the electrical
characteristics and energy generation of a single photovol-
taic module equipped with a concentrator with a geometric
concentration ratio Cg = 12 and an optical efficiency of 0.7,
and of an array consisting of twelve identical PV modules.
In both cases, the total active area is the same. From an
electrical connection perspective, the twelve modules can
be arranged in various configurations that primarily affect
nominal voltage and current values; however, the total
nominal power remains unchanged. A series configuration
is selected as the most common arrangement.
The following figures present the families of power-voltage
characteristic curves for the two mentioned configurations
under various solar irradiance and temperature conditions.
The photovoltaic module considered is the A10Green Tech-
nology A10J-S72-175 with a nominal power of 175 W. The
characteristics were obtained through simulations con-
ducted in MATLAB/Simulink. The “PV Array” block from the
“Simscape” library was used to model the PV modules in all
the cases. The model accounts for the dependence of mod-
ule temperature on irradiance, as given in Equation (1). The
solar concentrator was modeled with a geometric concen-
tration ratio of Cg = 12 and an optical efficiency of 0.7, cor-
responding to a solar concentration factor (number of suns)
of X = 8.4.
As shown in Figs. 1 and 2, the maximum output power of
the twelve-module array is generally approximately twice
that of the single module equipped with a concentrator.
Moreover, the lower the temperature and irradiance, the
smaller the difference between the power of the concen-
trating-module configuration and that of the module array.
This behavior is explained by both optical losses in the con-
centrator and degradation of PV module performance at el-
evated temperatures.
To evaluate potential loss reductions, Fig. 3 presents the
power characteristics of a module equipped with a concen-
trator having an optical efficiency of 0.95 – representative
of the most advanced existing solutions [7, 11] – and em-
ploying a cooling system that maintains the module tem-
perature equal to that of a non-concentrating module un-
der the same irradiance and ambient temperature
conditions. It can be observed that the performance of such
an enhanced concentrator-based system is significantly
better than that of the previously considered concentrator
configuration; however, it still underperforms the module
array at high irradiance levels and approaches the array
performance only at low irradiance.
It is also noteworthy that the slope of the power curve at
the maximum power point is flatter for the module with a
concentrator. This reduces the accuracy requirements for
the maximum power point tracking (MPPT) system and
may potentially decrease losses associated with non-opti-
mal operating-point detection.
143
Відновлювана енергетика. № 4/2025 | Сонячна енергетика
а б
Fig. 1. Power-voltage curve for: а) PV module with solar concentrator, b) sequence of 12 PV modules at the ambient
temperature of 25 0С and solar irradiance range of 100 to 1000 W/m2
а б
Fig. 2. Power-voltage curve for: а) PV module with solar concentrator, b) sequence of 12 PV modules at the solar
irradiance 800 W/m2 and ambient temperature range of -30 to 30 0С
а б
Fig. 3. Power-voltage curve for the cooled PV module and concentrator with optical efficiency 0.95 for: а) ambient
temperature 25 0С and solar irradiation range of 100 to 1000 W/m2, b) solar irradiation 800 W/m2 and ambient
temperature range of -30 to 30 0С
144
Відновлювана енергетика. № 4/2025 | Сонячна енергетика
Comparison of Annual Energy Output of a Single PV Mod-
ule with a Concentrator and a PV Module Array
To comparatively evaluate the energy-generation poten-
tial of a single photovoltaic module equipped with a con-
centrator and that of a photovoltaic module array, an an-
nual energy-yield simulation was performed using the
methodology described in [14]. The following configura-
tions were examined: 1) a PV module with a concentrator
having a geometric concentration ratio of Cg = 12 and an
optical efficiency of 0.7 (X = 8.4 suns), without a cooling
system (hereafter referred to as the “low-efficiency con-
centrator”); 2) a PV module with a concentrator having a
geometric concentration ratio of Cg = 12 and an optical ef-
ficiency of 0.95 (X = 11.4 suns), combined with a cooling
system that compensates for the thermal effects of in-
creased irradiance (the “high-efficiency concentrator”); 3)
an array of twelve photovoltaic modules connected in se-
ries.
The module model corresponds to the A10Green Technol-
ogy A10J-S72-175. Climatic data for the simulation were ob-
tained from [12] and include hourly direct normal irradi-
ance value s on a horizontal surface and ambient
temperatures for the geographic coordinates of Kyiv city in
2019. The results are summarized in Table.
Table. Annual electricity output of 12 sequentially connected PV modules, a PV module equipped with a
“low-efficiency” solar concentrator, and a cooled PV module with a “high-efficiency” solar concentrator
12-module
PV array
PV module with a
“low-efficiency” con-
centrator
PV module with a “high-ef-
ficiency” concentrator
Month Day-
light
hours,
h
Average
tempera-
ture, 0С
Average
solar irradi-
ance,
W/m2
Monthly
yield,
kW·h
Monthly
yield,
kW·h
Share of
yield rela-
tive to the
12-module
PV array
Monthly
yield, kW·h
Share of
yield relative
to the 12-
module PV
array
January 302 -7 107 73.4 52.8 72% 72.8 99%
February 304 -2 182 124.9 86.7 69% 120.1 96%
March 395 5 236 206.6 139.6 68% 193.8 94%
April 439 11 310 293.6 190.8 65% 266.2 91%
May 496 18 328 341.6 219.3 64% 307.3 90%
June 536 24 382 419.9 260.7 62% 366.4 87%
July 518 22 393 422.9 260.7 62% 366.8 87%
August 479 23 380 375.8 233.4 62% 328.2 87%
Septem-
ber
408 18 306 261.9 170.4 65% 238.0 91%
October 362 13 232 178.6 121.1 68% 168.6 94%
November 300 5 135 87.9 62.7 71% 86.7 99%
December 269 2 87 50.9 37.1 73% 51.2 101%
Annual yield, kW·h 2,837.9 1,835.4 65% 2,566.2 90%
As shown in Table, on an annual basis, a single PV module
equipped with a concentrator of geometric concentration
ratio of Cg = 12 generates only 65% of the energy produced
by twelve identical non-concentrating PV modules,
whereas an idealized cooled concentrator system reaches
approximately 90%. Furthermore, the lower the ambient
temperature and irradiance, the higher the relative effec-
tiveness of the PV module with a concentrator. It can be
estimated that a module equipped with a conventional
(low-efficiency) concentrator produces approximately the
same amount of energy as eight identical non-concentrat-
ing PV modules. Thus, the energy yield per unit of active
area for a simple concentrator without supplemental cool-
ing is roughly 1.5 times lower than that of an array of pho-
tovoltaic modules with the same total active area. Although
financial assessments fall outside the scope of this work, it
is reasonable to assume that, given the adoption of a sim-
ple, low-cost concentrator without a cooling system, such a
configuration may be considered viable in applications
where installation cost is of greater concern than available
surface area.
Conclusion
The use of a standard commercially available photovoltaic
module equipped with a solar concentrator with approxi-
mately 0.7 optical efficiency and a geometric concentration
ratio of 12 yields energy comparable to that of eight identi-
cal non-concentrating modules. This configuration does not
require a cooling system and employs a concentrator aper-
ture area equivalent to the overall active area of twelve
analogous photovoltaic modules. Consequently, the energy
generation per unit area drops by approximately 35%; how-
ever, the installation cost is expected to be significantly
lower due to the comparatively low cost of the concentra-
tor. In addition, the flatter slope of the output characteris-
tics for the module with a concentrator reduces the accu-
racy requirements for maximum power point tracking
145
Відновлювана енергетика. № 4/2025 | Сонячна енергетика
(MPPT) and decreases the potential power losses arising
from suboptimal operating point detection.
When a concentrator with optical efficiency comparable to
the best current technology is employed, together with a
cooling system capable of maintaining reduced module
temperatures, the resulting energy generation is only
about 10% lower than that of an array of photovoltaic mod-
ules. Nevertheless, the commercial feasibility of such a so-
lution is difficult to assess due to the increased complexity
of the concentrator and the required cooling infrastructure.
REFERENCES
1. Ejaz A., Babar H., Ali H.M., J amil F., Janjua M.M., Fattah
I.M.R., Said Z, Li C. Concentrated photovoltaics as light
harvesters: Outlook, recent progress, and challenges.
Sustainable Energy Technologies and Assessments. Vol-
ume 46, August 2021, 101199. DOI:
https://doi.org/10.1016/j.seta.2021.101199
2. Xiao J., Wei X., Lu Z., Yu W., Wu H. A review of available
methods for surface shape measurement of solar con-
centrator in solar thermal power applications. Renewa-
ble and Sustainable Energy Reviews. Volume 16, Issue
5, June 2012, Pp. 2539-2544. DOI:
https://doi.org/10.1016/j.rser.2012.01.063
3. Ceylan I., Gürel A.E., Ergün A., Tabak A. Performance
analysis of a concentrated photovoltaic and thermal
system. Solar Energy. Volume 129, May 2016, Pp. 217-
223. DOI:
https://doi.org/10.1016/j.solener.2016.02.010
4. Cameron W.J., Reddy K. S., Mallick T.K. Review of high
concentration photovoltaic thermal hybrid systems for
highly efficient energy cogeneration. Renewable and
Sustainable Energy Reviews. Volume 163, July 022,
112512. DOI:
https://doi.org/10.1016/j.rser.2022.112512
5. Zubi G, J.L., Fracastoro G.V. High concentration photo-
voltaic systems applying III–V cells. Renewable and Sus-
tainable Energy Reviews. Volume 13, Issue 9, December
2009, Pp. 2645-2652. DOI:
https://doi.org/10.1016/j.rser.2009.07.002
6. Solanki C.S., Sangani C.S., Gunashekar D., Antony G. En-
hanced heat dissipation of V-trough PV modules for bet-
ter performance. Solar Energy Materials and Solar Cells.
Volume 92, Issue 12, December 2008, Pp. 1634-1638.
DOI: https://doi.org/10.1016/j.solmat.2008.07.022
7. Iqbal W., Ullah I., Shin S. Optical Developments in Con-
centrator Photovoltaic Systems—A Review. Sustainabil-
ity. 2023, Volume 15, Issue 13, 10554. DOI:
https://doi.org/10.3390/su151310554
8. Jakhar S., Soni M.S., Gakkhar N. Historical and recent
development of concentrating photovoltaic cooling
technologies. Renewable and Sustainable Energy Re-
views. Volume 60, July 2016, Pp. 41-59. DOI:
https://doi.org/10.1016/j.rser.2016.01.083
9. Salilih E. M., Birhane Y. T. Modeling and Analysis of
Photo-Voltaic Solar Panel under Constant Electric Load.
Journal of Renewable Energy. Volume 2019, Article ID
9639480, 10 pages. DOI:
https://doi.org/10.1155/2019/9639480
10. Ghosh S.M., Shawon M.H., Rahman A., Abdullah R.
Modeling of PV Array and Analysis of Different Parame-
ters. International Journal of Advancements in Research
& Technology, Volume 2, Issue 5, May-2013. ISSN 2278-
7763. Pp. 358-363.
11. Li Y., A Study on the Optical Efficiency of Solar Concen-
trators Based on Ray Tracing Method. Highlights in Sci-
ence, Engineering and Technology. 2024. Volume 83.
Pp. 33-42. DOI: https://doi.org/10.54097/nz27b7'85
12. https://www.renewables.ninja/
13. Khamooshi M., Salati H., Egelioglu F., Faghiri A.H., Tar-
abishi J., Babadi S. A Review of Solar Photovoltaic Con-
centrators. International Journal of Photoenergy
(Hindawi). Volume 2014, Article ID 958521, 17 pages.
DOI: http://dx.doi.org/10.1155/2014/958521
14. Kuznietsov М. Simplification of photovoltaic module
electrical models for power generation forecasting
tasks. Vidnovlyuvana enerhetyka. 2025. No.2. Pp. 126-
132. DOI: https://doi.org/10.36296/1819-
8058.2025.2(81).126-132 [in Ukr]
https://www.sciencedirect.com/author/6507310480/jose-luis-bernal-agustin
|
| id | veorgua-article-580 |
| institution | Vidnovluvana energetika |
| keywords_txt_mv | keywords |
| language | Ukrainian |
| last_indexed | 2026-07-19T01:17:43Z |
| publishDate | 2025 |
| publisher | Institute of Renewable Energy National Academy of Sciences of Ukraine |
| record_format | ojs |
| resource_txt_mv | veorgua/99/bdae8afe6fbc5c3f302a0d4965f29099.pdf |
| spelling | veorgua-article-5802026-07-18T06:32:23Z MODELING OF ELECTRICAL CHARACTERISTICS OF A SILICON PHOTOVOLTAIC MODULE EQUIPPED WITH A SOLAR RADIATION CONCENTRATOR МОДЕЛЮВАННЯ ЕЛЕКТРИЧНИХ ХАРАКТЕРИСТИК КРЕМНІЄВОГО ФОТОЕЛЕКТРИЧНОГО МОДУЛЯ З КОНЦЕНТРАТОРОМ СОНЯЧНОГО ВИПРОМІНЮВАННЯ Kuznietsov , M. renewable energy sources, solar power plant, solar radiation concentrator, electricity generation forecast. відновлювані джерела енергії, фотоелектрична станція, концентратор сонячного ви- промінювання, прогноз генерації електроенергії. The purpose of this article is to analyze the electrical characteristics of a photovoltaic module with a solar radiation concentrator. The object of the study is a simple commercially available photovoltaic module with the simplest solar radiation concentrator without additional cooling systems, which makes this solution technically simple and commercially attractive. The task is to evaluate the technical feasibility of such a solution. The study provides comparative characteristics of the dependence of power on voltage and monthly electricity generation of the mentioned concentrator system compared to a traditional solution – a set of photovoltaic modules connected in series. To assess the impact of the concentrator itself on the characteristics of the module, a comparison with a certain idealized solution is also made. As a conclusion, the feasibility of solar energy concentrators with conventional photovoltaic modules is demonstrated, since despite a 35% drop in electricity generation per unit area, the cost of such a solution is expected to be lower, because one module with a concentrator will be able to generate as much energy as 8 modules without radiation concentration. Bibliography 14. Метою роботи є аналіз електричних характеристик фотоелектричного модуля з концентратором сонячної енергії. Об’єкт дослідження – простий фотоелектричний модуль з найпростішим концентратором сонячної енергії без додаткових систем охолодження, що робить таке рішення технічно простим і комерційно привабливим. Задача роботи полягає в оцінці технічної доцільності такого рішення. У роботі наводяться порівняльні характеристики залежності потужності від напруги та помісячної генерації електроенергії зазначеного рішення порівняно з традиційним рішенням – набором послідовно включених фотоелектричних модулів. Для оцінки впливу самого концентратора на характеристики модуля наведено також порівняння з певним ідеалізованим рішенням. Визначено доцільність використання концентраторів сонячної енергії зі звичайними фотоелектричними модулями, оскільки попри 35%-ве падіння генерації електроенергії з одиниці площі вартість такого рішення очікується меншою: один модуль з концентратором передбачено генерує стільки ж енергії, скільки вісім модулів без концентратора. Бібл.14. Institute of Renewable Energy National Academy of Sciences of Ukraine 2025-12-27 Article Article application/pdf https://ve.org.ua/index.php/journal/article/view/580 10.36296/1819-8058.2025.4(83).136-145 Vidnovluvana energetika ; No. 4(83) (2025): Scientific and applied Journal renewable energy ; 136-145 Возобновляемая энергетика; ##issue.no## 4(83) (2025): Scientific and applied Journal renewable energy ; 136-145 Відновлювана енергетика; № 4(83) (2025): Науково-прикладний журнал Відновлювана енергетика; 136-145 2664-8172 1819-8058 10.36296/1819-8058.2025.4(83) uk https://ve.org.ua/index.php/journal/article/view/580/491 Copyright (c) 2025 M. Kuznietsov https://creativecommons.org/licenses/by-nc-nd/4.0 |
| spellingShingle | renewable energy sources solar power plant solar radiation concentrator electricity generation forecast. Kuznietsov , M. MODELING OF ELECTRICAL CHARACTERISTICS OF A SILICON PHOTOVOLTAIC MODULE EQUIPPED WITH A SOLAR RADIATION CONCENTRATOR |
| title | MODELING OF ELECTRICAL CHARACTERISTICS OF A SILICON PHOTOVOLTAIC MODULE EQUIPPED WITH A SOLAR RADIATION CONCENTRATOR |
| title_alt | МОДЕЛЮВАННЯ ЕЛЕКТРИЧНИХ ХАРАКТЕРИСТИК КРЕМНІЄВОГО ФОТОЕЛЕКТРИЧНОГО МОДУЛЯ З КОНЦЕНТРАТОРОМ СОНЯЧНОГО ВИПРОМІНЮВАННЯ |
| title_full | MODELING OF ELECTRICAL CHARACTERISTICS OF A SILICON PHOTOVOLTAIC MODULE EQUIPPED WITH A SOLAR RADIATION CONCENTRATOR |
| title_fullStr | MODELING OF ELECTRICAL CHARACTERISTICS OF A SILICON PHOTOVOLTAIC MODULE EQUIPPED WITH A SOLAR RADIATION CONCENTRATOR |
| title_full_unstemmed | MODELING OF ELECTRICAL CHARACTERISTICS OF A SILICON PHOTOVOLTAIC MODULE EQUIPPED WITH A SOLAR RADIATION CONCENTRATOR |
| title_short | MODELING OF ELECTRICAL CHARACTERISTICS OF A SILICON PHOTOVOLTAIC MODULE EQUIPPED WITH A SOLAR RADIATION CONCENTRATOR |
| title_sort | modeling of electrical characteristics of a silicon photovoltaic module equipped with a solar radiation concentrator |
| topic | renewable energy sources solar power plant solar radiation concentrator electricity generation forecast. |
| topic_facet | renewable energy sources solar power plant solar radiation concentrator electricity generation forecast. відновлювані джерела енергії фотоелектрична станція концентратор сонячного ви- промінювання прогноз генерації електроенергії. |
| url | https://ve.org.ua/index.php/journal/article/view/580 |
| work_keys_str_mv | AT kuznietsovm modelingofelectricalcharacteristicsofasiliconphotovoltaicmoduleequippedwithasolarradiationconcentrator AT kuznietsovm modelûvannâelektričnihharakteristikkremníêvogofotoelektričnogomodulâzkoncentratoromsonâčnogovipromínûvannâ |