A pulse transformer for a 10 MW klystron power supply
The design and test results of the Pulse Transformer (PT) for the klystron with a voltage of 120 kV, klystron current of 130 A and a pulse duration of 1.4 ms is presented. The PT design was realized with taking into account the following requirements: no edge effect on the secondary winding; no over...